Infusion Pump CI-60E

Infusion Pump CI-60E

– 3.5” colorful touch screen, easy to operate with human-computer interface.

– Unique doorless design, visible place the IV set directly, convenient and quick.

– Dual CPU control, IP34 dustproof and waterproof design. AC/DC power, Larger battery capacity 2600 mAh. long working time.

– Reduce the bubbles error alarm because horizontal place the IV set design.

– Very Light weight only 1.3 KG, small and exquisite, convenient to carry and transport.

– DPS dynamic pressure monitoring, real-time display of the current pressure value.

– Adopt German high-end medical-grade motor drive chip! Special patented technology of silent noise reduction as low as 12dB, anti-jitter to achieve smooth operation of high and low speed, power saving, micro complementary stepping and more accurate infusion, reduce resonance to save energy and reduce consumption, efficient temperature reduction to keep the motor at a constant temperature.

– New independent 3 stage peristaltic device design with exclusive patented technology and First one in the global market, which it making infusion set stress evenly and improving infusion accuracy and extending the life of infusion pump and IV set, reduce workload and make the patient more comfortable in infusion process.

Product Information

Technical Specification
Infusion ModeRate Mode
PowerAC: 100~240V,   External DC Power: 12V~15V
Battery2600mAh, working 10 hours in 25ml/h speed.
CPUDouble CPU.
IP34warterproof / dustproof/shockproof.
Flow Rate range0.1~1200.00ml/h, increment 0.01ml/h.
VTBI0.1-9999.99ml
Time1s-99h59min
KVO0.1~5.0ml/h,increment 0.1ml/h.
Accuracy±5%  (use the IV set calibrated)
Purge0.1-1200ml/h
IV setsDia3-5mm or setting
Bolus rate0.1~1200ml/h
bolus modelAutomatic/Manual bolus available
Anti-bolusAutomatically reduce the tube pressure when the tube is blocked
Bubble sizeAdjustable 50/100/250/500/800μl, Ultrasonic detection.
Occlusion pressure detectionAdjustable Low /Medium /High, Double Pressure detection.
History Record2000 above
Night modesetting and adjustable
IV Set2 built-in brand for choice,  and can User defined:  Common IV set / Specified IV set /  Light-proof IV set / Precision IV set.
AlarmAir in Line / Downstream Occlusion / UPstream Occlusion / No Battery / VTBI Completed / KVO Finished / System Error / No Infusion Tube / Standby Time Expired / Reminder / Low Battery /No Battery Inserted / Time Near End / No AC Power.
Atmospheric pressure40~120Kpa
Temperature-20℃-55℃
Relative humidity10%-95%
DimensionL165 × W103 × H100mm
Net Weight1.3 kg (with battery)