Vet Monitor VM15
– 15 Inch Color wide screen TFT display
– Small and cute appearance, excellent portability
– Unique human voice alarm Silent fanless design
– More than 4 hours of operation with battery
– 720 hours trend and 12 hours of all waveforms
– Support USB data output,wire and wireless network
– 14 languages:English, French, German and etc
Configuration:
> 5-lead ECG,SpO2,NIBP, TEMP, Resp,PR; Li-ion battery
Options:
> 2-IBP, C.O, EtCO2; Thermal Recorder.
Categories All Products, Patient Monitoring & Life Support, Vet Monitor
Product Information
Technical Specification | |
ECG | |
Lead model | 5 Leads (I, II, III, AVR, AVL,AVF, V) |
Gain: | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV |
Heart Rate | |
Measure range | Adult:15-300 bpm, Neonatal/Pediatric: 15-350 bpm |
Accuracy | 1% |
Resolution | 1 bpm |
Sensitivity | > 200 μVP-P |
Differential Input Impedance | > 5 MΩ |
CMRR | Diagnostic Mode>90 dB, Monitor Mode>110 dB, Surgery, Mode>110 dB |
Offset Potential | ± 300mV |
Leakage Current | < 10 μA |
Pace Pulse Detect | Range:± 2~± 700mV, Width:0.1~2ms, Rise Time:10-100 μs |
Pace Pulse Rejection | Range:± 2~± 700mV, Width:0.1~2ms, Rise Time:10-100 μs |
Baseline Recovery | < 3 s After defibrillation. |
ECG Signal Range | ± 5 mV (Vp-p) |
Bandwidth | Surgery: 1-20 Hz, Monitor: 0.5-40 Hz, Diagnostic: 0.05-130 Hz |
Calibration Signal: | 1 mV p-p, ± 5% accuracy |
ST measurement: | Range:-2.0-+2.0 mV |
Accuracy | -0.8mV-+0.8mV,± 0.02mVor± 10%, which is greater;Other Range: unspecified |
Arrhythmia | 13 Types: ASYSTOLE, VFIB/VTAC, COUTPLET, BIGMINY,TRIGEMINY, R ON T, VT >2, BRADY, MISSED BEATS, PNP, PNC |
RESP | |
Method | Impedance between RA-LL or RA-LA |
Differential Input Impedance | >2.5 ΜΩ |
Respiration Impedance Range | 0.3-3Ω |
Base Impedance Range | 200 Ω-2000Ω |
Bandwidth | 0.3-2 Hz |
Gain | x0.25, x0.500, x1, x2, x4 |
Respiration Rate | |
Measurement Range | Adult:0 ~120 BrPM,Neonatal / Pediatric: 0~150 BrPM |
Resolution | 1 BrPM |
Accuracy | 0-6 BrPM: unspecified, 7-150 BrPM: ± 2 BrPM or ± 2% use the greater. |
Inspiriting current | < 300 μA RMS max |
Apnea Alarm | 10 -40 s |
NIBP | |
Method | Oscillometry |
Measure Mode | Manual, Auto, STAT |
Measure Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min |
Measure Period in STAT Mode | 5 min |
Pulse Rate Range | 40 ~240 bpm |
Measure and Alarm Range | |
Adult Mode | SYS:40~280 mmHg, DIA:10~220 mmHg, MEAN:20~240 mmHg |
Pediatric Mode | SYS:40~220 mmHg, DIA:10~160 mmHg, MEAN:20~170 mmHg |
Neonatal Mode | SYS:35~135 mmHg, DIA:10~100 mmHg, MEAN:20 ~110 mmHg |
Static pressure accuracy | ± 3mmHg |
Resolution | 1mmHg |
Accuracy | Maximum Mean Error: ± 5mmHg, Maximum Standard Deviation: 8mmHg |
Overpressure Protection | Adult:300 mmHg, Pediatric:240 mmHg, Neonatal:150 mmHg |
SpO2 | |
Measurement Range | 0~100% |
Resolution | 1% |
Accuracy | 70% ~100% ± 2 %, 0%~69%: unspecified |
Pulse Rate Measure and Alarm Range | 20-250bpm |
Resolution | 1bpm |
Accuracy | ± 3bpm |
TEMP | |
Channel | 2 |
Measure and Alarm Range | 0~50 ℃ |
Resolution | 0.1℃ |
Accuracy | (no sensor): ± 0.1℃(25℃ – 45℃), ± 0.2℃(other);
(include sensor): ±0.2℃(32℃ – 42℃) ,± 0.3℃ (other) |