Vet Monitor VM70
– Classic display: 12.1 inch LCD display with multiple display format
– HD display:High definition display 1024 * 768
– Simplified operation: Based on classic clinical design, UI operation is ultra simplified
– Reliable quality: passed the rigorous multi application ccenarios test, proved to be durable and helpful
– Long operation hour: with inbuilt 8000mAh lithium battery, machine can be last for 4 hour after fully charged
– Patented ECG specialized algorithm, passed AHA/MIT-BIH database verification
– NIBP with anti-interference and anti-motion algorithm, generating accurate blood readings fastly
– SpO2 with advanced anti-interference and lower perfution detection technology
– Based on black body light source technology, CO2 is with improved accuracy and reliability
Advanced measurement technology
– Applicable to adult, pediatric and neonate
– Accurate measurement in 0.075% low perfusion index, excellent anti-motion capability, generating more accurate, more stable, and more reliable data
– Neonate specilized NIBP/SPO2 module
– CO2 min. sampling volume 50ml/Min
– CO2 double channel sensor, iPX4 waterproof level, Anti-shock, anti-drop, easy to use
– IBP measurement range: -50~400mmHg
– Heart rate measurement upto 350 bpm
Product Configuration
– Standard configuration:ECG、SpO2、NIBP、RESP、TEMP、PR
– Optional configuration:CO2、IBP、C.O. AG
– Other:Trolley, wall mount
Product Information
SpO2 | |
Measurement Accuracy | ±2%( 70% ~ 100% ),undefiend(0 ~ 69%) |
Measurement Range | 0–100% |
Alarm Range | Consistent with the display range, the alarm limit setting step length is 1% |
Pulse rate | |
Measurement Range | 20bpm ~ 254bpm |
Alarm Range | Consistent with the display range, the alarm limit is set to a step length of 1bpm |
Speed of refresh | 1 s |
Measurement Accuracy | ±2 bpm |
Pulse rate Mean | 8 s |
TEMP | |
Measurement Accuracy | ±0.2℃(0℃~50℃) |
Measurement Range | 0℃~50℃ |
Unit of measurement | ℃,℉ |
Alarm delay time | <10s |
NIBP | |
Method of measurement | oscillation |
Parameter of measurement | Systolic, diastolic and mean arterial pressure |
Unit | mmHg, kPa |
Mode of operation | Manual, automatic, and continuous |
Systolic blood pressure range | Adult: 30 mmHg ~ 270mmHg
Child:30 mmHg ~ 230mmHg Neonate:30 mmHg ~ 135mmHg |
Diastolic blood pressure range | Adult:10 mmHg ~ 220mmHg
Child:10 mmHg ~ 165mmHg Neonate:30 mmHg ~ 100mmHg |
Mean pressure range | Adult:10 mmHg ~ 240mmHg
Child:10 mmHg ~ 175mmHg Neonate:30 mmHg ~ 110mmHg |
Measurement Accuracy | The maximum mean error is ±5 mmHg or ±4%, with the highest absolute value |
Measurement Range | Consistent with the display range, the alarm limit setting step length is 1mmHg |
Alarm delay time | <10s |
Cuff pressure range | 0 mmHg ~ 300 mmHg |
Cuff inflation rate | <50mmHg/s |
Static pressure measurement error | ±3mmHg (Overpressure protection is not achieved) |
Resolution of display | 1mmHg |
Repeatability | When measured at static continuous low pressure, the difference between repeated readings at each point within the scale range should not be greater than 4 mmHg |
Pressure sensor accuracy | The maximum error for pressure measurements in the cuff should be ±3 mmHg at any point in the range, regardless of boost or drop |
Pulse rate measurement | The measuring range is 40 bpm ~ 240 bpm, the measuring accuracy is ± 2% or ±2 bpm, the absolute value of both should be greater |
ECG | |
Lead | 3/5 lead |
Waveform | 2 channel |
Gain | X0.25,X0.5,X1,X2,X4 |
Speed | 12.5mm/s;25mm/s;20mm/s |
HR range | 15~300BPM(AUD);15~350BPM(NEO) |
Filter mode | DIA(0.05~100Hz);MON(0.5~40Hz);SUR(1~25Hz) |
Protection | Anti-electric knife;Anti-defibrillation protection;5000V isolation strength |
ST diagnosis | -2.5mV~2.5mV; Arrhythmia analysis; Pacing detection |
RESP | |
Principle | Impedance Breathing |
Range | 0~120RPM |
Choking alarm | 20s~60s optional,internval 5s |
CO2 | Applicable to ADU, PED, and NEO |
CO2 range | 0~150mmHg; |
accuracy | ± 2mmHg(0~40mmHg), ± 5%(41~100mmHg), ± 8%(101~150mmHg) |
Respiratory rate range | 0~150RPM |
Sampling flow | 50ml/Min |
Accuracy | ±2RPM |
IBP | Support dual-channel IBP simultaneous measurement |
IBP range | -50~400mmHg;accuracy: ± 3mmHg(0~40mmHg) |
measurement modes | ABP、CVP、ICP、LAP,etc |
Pulse rate range | 20~254BPM |
Accurate | ±2RPM |