Vital Signs Monitor YC-V3A
– 3.5″ LED screen with resolution 480*320;
– Available to measure SpO2, PR, blood pressure, body temperature;
– Up to 24 working hours of battery;
– Suitable for Neonatal,Child and Adult;
– Display the PI indexto help medical staffjudge the reliability of the measurement;
– Weak perfusion performance can reach 0.075%,with excellent anti-motion performance;
– Powerful data function,support up to 28,000 pieces;
– Parameter: SPO2,NIBP,TEMP.
Categories All Products, Patient Monitoring & Life Support, Vet Monitor
Product Information
| SpO2 | |
| Measurement Accuracy | ±2%( 70% ~ 100% ),undefiend(0 ~ 69%) |
| Measurement Range | 0–100% |
| Alarm Range | Consistent with the display range, the alarm limit setting step length is 1% |
| Pulse rate | |
| Measurement Range | 20bpm ~ 254bpm |
| Alarm Range | Consistent with the display range, the alarm limit is set to a step length of 1bpm |
| Speed of refresh | 1 s |
| Measurement Accuracy | ±3 bpm |
| Pulse rate Mean | 8 s |
| NIBP | |
| Method of measurement | oscillation |
| Parameter of measurement | Systolic, diastolic and mean arterial pressure |
| Unit | mmHg, kPa |
| Mode of operation | Manual, automatic, and continuous |
| Systolic blood pressure range | Adult: 30 mmHg ~ 270mmHg
Child:30 mmHg ~ 230mmHg Neonate:30 mmHg ~ 135mmHg |
| Diastolic blood pressure range | Adult:10 mmHg ~ 220mmHg
Child:10 mmHg ~ 165mmHg Neonate:30 mmHg ~ 100mmHg |
| Mean pressure range | Adult:10 mmHg ~ 240mmHg
Child:10 mmHg ~ 175mmHg Neonate:30 mmHg ~ 110mmHg |
| Measurement Accuracy | The maximum mean error is ±5 mmHg or ±4%, with the highest absolute value |
| Measurement Range | Consistent with the display range, the alarm limit setting step length is 1mmHg |
| Alarm delay time | <10s |
| Cuff pressure range | 0 mmHg ~ 300 mmHg |
| Cuff inflation rate | <50mmHg/s |
| Static pressure measurement error | ±3mmHg (Overpressure protection is not achieved) |
| Resolution of display | 1mmHg |
| Repeatability | When measured at static continuous low pressure, the difference between repeated readings at each point within the scale range should not be greater than 4 mmHg |
| Pressure sensor accuracy | The maximum error for pressure measurements in the cuff should be ±3 mmHg at any point in the range, regardless of boost or drop |
| Pulse rate measurement | The measuring range is 40 bpm ~ 240 bpm, the measuring accuracy is ± 2% or ±2 bpm, the absolute value of both should be greater |
Video Presentation
Send Us Message Send us a message if you have any questions or request a quote. Our experts will give you a reply within 24 hours and help you select the right valve you want.
- +86 15012852057
- sales@vetpoct.com




