Vital Signs Monitor YC-V3A

Vital Signs Monitor YC-V3A

– 3.5″ LED screen with resolution 480*320;

– Available to measure SpO2, PR, blood pressure, body temperature;

– Up to 24 working hours of battery;

– Suitable for Neonatal,Child and Adult;

– Display the PI indexto help medical staffjudge the reliability of the measurement;

– Weak perfusion performance can reach 0.075%,with excellent anti-motion performance;

– Powerful data function,support up to 28,000 pieces;

– Parameter: SPO2,NIBP,TEMP.

Product Information

SpO2
Measurement Accuracy ±2%( 70% ~ 100% ),undefiend(0 ~ 69%)
Measurement Range0–100%
Alarm Range Consistent with the display range, the alarm limit setting step length is 1%
Pulse rate
Measurement Range20bpm ~ 254bpm
Alarm RangeConsistent with the display range, the alarm limit is set to a step length of 1bpm
Speed of refresh1 s
Measurement Accuracy±3 bpm
Pulse rate Mean8 s
NIBP
Method of measurementoscillation
Parameter of measurementSystolic, diastolic and mean arterial pressure
UnitmmHg, kPa
Mode of operationManual, automatic, and continuous
Systolic blood pressure rangeAdult: 30 mmHg ~ 270mmHg

 

Child:30 mmHg ~ 230mmHg

Neonate:30 mmHg ~ 135mmHg

Diastolic blood pressure rangeAdult:10 mmHg ~ 220mmHg

 

Child:10 mmHg ~ 165mmHg

Neonate:30 mmHg ~ 100mmHg

Mean pressure rangeAdult:10 mmHg ~ 240mmHg

 

Child:10 mmHg ~ 175mmHg

Neonate:30 mmHg ~ 110mmHg

Measurement AccuracyThe maximum mean error is ±5 mmHg or ±4%, with the highest absolute value
Measurement RangeConsistent with the display range, the alarm limit setting step length is 1mmHg
Alarm delay time<10s
Cuff pressure range0 mmHg ~ 300 mmHg
Cuff inflation rate<50mmHg/s
Static pressure measurement error±3mmHg (Overpressure protection is not achieved)
Resolution of display1mmHg
RepeatabilityWhen measured at static continuous low pressure, the difference between repeated readings at each point within the scale range should not be greater than 4 mmHg
Pressure sensor accuracyThe maximum error for pressure measurements in the cuff should be ±3 mmHg at any point in the range, regardless of boost or drop
Pulse rate measurementThe measuring range is 40 bpm ~ 240 bpm, the measuring accuracy is ± 2% or ±2 bpm, the absolute value of both should be greater